top of page
DSC02125.jpg

Our Products

ERBE Erbotom ICC 350

ERBE Erbotom ICC 350

Call For PRICING

 

The top-of-the-line ERBOTOM ICC 350 heads ERBE’s family of units for HF surgery. They’ve given it one-of-a-kind functionality for all-around use, with the features and abilities developed in close teamwork with leading surgeons from many different medical disciplines.

The ICC 350 has received worldwide attention and recognition; it is a step forward from conventional surgical methods and opens the way for new ones.

    • General surgery
    • Dermatology
    • Endoscopy
    • Gastroenterology
    • Vascular Surgery
    • Genecology
    • Neurosurgery
    • Plastic Surgery
    • Oral surgery
  • Dimensions

    • Dimensions (W x H x D): 410 × 152 × 368 mm
    • Weight: 10.0 kg

    Coagulation

    • HF power adjustment: With up/down increment keys

    Cutting

    • HF power adjustment: With up/down increment keys
    • Form of HF voltage: Sine-shaped
    • Nominal frequency of HF voltage: 330 kHz
    • Cutting quality: 4 coagulation effects, selectable by key
    • Constancy of the coagulation effects: Automatically regulated
    • Support for initial incision and cutting: PPS, PowerPeakSystem
    • Monopolar AUTO CUT: With automatic voltage control
    • Monopolar HIGH CUT: with automatic arc control
    • Nominal HF output: 300 watts at 500 ohms
    • Peak HF power with PPS: 400 watts at 500 ohms
    • Monopolar ENDO CUT: 200 watts at max 200 ohms
    • BIPOLAR AUTO CUT: With automatic voltage control
    • Nominal HF output: 100 watts at 500 ohms

    Electrical

    • Rated power voltage: 240V/230V/115V/110V/100V± 10%
    • Rated power frequency: 50/60 Hz
    • Power current: 4.0 A at 230 - 240 V/8.0 A at 100-115 V
    • Power consumption in Standby mode: 25 watts
    • Power consumption at max. HF power: 620 watts 920 VA
    • Current consumption in Standby mode: 150 mA at 230 - 240V/300 mA at 100-115 V
    • Potential equalization terminal: Yes
    • Power fuses: 2 slow burn, 4 A at 230 - 240 V/8 A at 100-115 V

    Monopolar SOFT COAG

    • Form of HF current: Sine-shaped
    • Nominal frequency of HF voltage: 300 kHz
    • Nominal HF output: 120 watts at 125 ohms
    • End of coagulation: with Pedal or AUTO STOP

    Monopolar FORCED COAG

    • Form of HF current: Pulse-modulated
    • Nominal frequency of HF voltage: 1 MHz
    • Nominal HF output: 120 atts at 350 ohms

    Monopolar SPRAY COAG

    • Form of HF current: Pulse-modulated
    • Nominal frequency of HF voltage: 1 MHz
    • Nominal HF output: 120 watts at 500 ohms

    Biopolar COAG

    • Form of HF current: Sine-shaped
    • Nominal frequency of HF voltage: 330 kHz
    • Nominal HF output: 120 watts at 125 ohms
    • Start of coagulation: By foot pedal or AUTO START
    • End of coagulation: By foot pedal or AUTO STOP

    Environmental Conditions for Storage

    • Temperature -40°C to + 70°C
    • Air humidity, relative 30% to 95%

    Environmental Conditions for Operating

    • Temperature +10°C to + 40°C
    • Air humidity, relative 30% to 75%, noncondensing

    Safety Precautions

    • Safety class: I, corresponds to DIN IEC 601-1
    • Type: CF, corresponds to DIN IEC 601-1
    • Software check of LF leakage current, Icritical: 0.05mA (only with capacitive grounding)
    • Software check of HF leakage current, Icritical: 150 mA/300MA
    • NESSY: Neutral electrode Safety System
    • Neutral electrode switching: Switch-selectable capacitively grounded or with floating power
    • Self-Check: Includes all safety-related subassemblies
Anchor 1