The GE Dash 5000 is a portable patient monitor. It has a built-in writer and can connect to the CARESCAPE network. It can connect with an optional wireless card, or by a wired ethernet connection. This Dash monitor unit can be used to monitor ECG, NIBP, impedance respiration, SpO2, and temperature. This Dash monitor optionally can monitor invasive pressure, BISx, and EtCO2.

    • Mainstream and low-flow sidestream CO2 measurement options for neonatal patients and adults.
    • Highly configurable. Add features and parameters for different acuity levels.
    • Advanced algorithms for all parameters.
    • 12.1-inch display.
    • Multiple mounting solutions.
    • Wired or wireless ECG acquisition.
  • Dimensions

    • Height: 11.3 in (28.7cm)
    • Width: 12.2 in (30.7 cm)
    • Depth: 9.4 in (23.9 cm)
    • Weight: 14 lbs. (6.4 kg)

    Battery

    • Type: Exchangeable Lithium-Ion
    • Number of Batteries: Up to 2
    • Weight: 0.8 lbs (0.36 kg) each
    • Voltage: 11.1 V (nominal)
    • Capacity: 3520 mAh
    • Charge Time: Less than 4 hours each
    • Run Time: 2.5 hours (5.0 hours with 2)

    Recorder

    • Method: Thermal dot array
    • Horizontal Resolution: 480 dots/in
    • Vertical Resolution: 200 dots/in
    • Waveform Channels: 4
    • Paper Width: 1.97 in (50 mm)
    • Paper Length: 100 ft (30 m)
    • Paper speed: 0.1, 0.5, 1, 5, 10, 12.5, 25, and 50 mm/sec

    Display

    • Size: 12.1 in diagonal
    • Type: Color LCD
    • Resolution: 800x600 pixels
    • Number of Traces: 6
    • Sweep Speed: 6.25, 12.5 or 25 mm/sec
    • Parameter Blocks Displayed: Up to 10

    Controls

    • Standard: Trim knob control plus 5 hard keys: Power, NBP Auto, Zero All, Silence Alarm/Admit, Print

    Invasive Blood Pressure (Optional)

    • Size: 12.1 in Channels: 2
    • Transducer Sites: ART, FEM, PA, CVP, RA, LA, ICP, SP. In neonatal mode UCA, and UVC.
    • Range: -25 mmHg to 300 mmHg
    • Offset: ±150 mmHg

    ECG

    • 5 Leadwire Cable: I, II, III, V, aVR, aVL, and aVF
    • 10 Leadwire Cable (12SL option): V2, V3, V4, V5 and V6
    • Voltage Range: ±0.5 mV to ±5 mV
    • Signal Width: 40 ms to 120 ms (Q to S)
    • Heart Rate Range: 30 to 300 BPM
    • Accuracy: ±1% or ±1BPM whichever is greater

    Noninvasive Blood Pressure

    • Technique: Oscillometric
    • Displayed Parameters: Systolic, diastolic, and mean pressures, time of last measurement
    • Modes: Manual, auto, and stat in adult and OR modes; manual and auto in neonatal mode
    • Systolic Pressure Range: Adult: 30 to 285 mmHg; Pediatric: 30 to 235 mmHg; Neonatal: 30 to 140 mmHg
    • Diastolic Pressure Range: Adult: 10 to 220 mmHg; Pediatric: 10 to 210 mmHg; Neonatal: 10 to 110 mmHg
    • Mean Pressure Range: Adult: 20 to 260 mmHg; Pediatric: 20 to 220 mmHg; Neonatal: 20 to 125 mmHg
    • Cuff Pressure Range: Adult: 294 ± 6 mmHg; Pediatric: 250 ± 5 mmHg; Neonatal: 147 ± 3 mmHg
    • Heart Rate Detection: 30 to 200 beats per minute

    BIS - Bispectral Index

    • Technology: Supports Aspect Medical BIS-x technology
    • Information Displayed: BIS, SQI, SR and SEF, EEG waveform
    • BIS Range: 0-100
    • Signal Quality Index (SQI) Range: 0-100
    • Suppression Ratio (SR) Range: 0-100%
    • Spectral Edge Frequency (SEF) Range: 0-30
    • Alarms: User selectable upper and lower BIS limits.

    SpO2

    • GE Pulse Range: Saturation: Pulse Rate: 0 - 100% SpO2; 30 - 250 beats per minute
    • Masimo SET Range: Saturation: 30 to 100% SpO2; Pulse Rate: 25 to 240 beats per minute; Perfusion: 0.02 to 20%
    • Nellcor Range: Saturation: 1 to 100% SpO2; Pulse Rate: 20 to 250 beats per minute; Perfusion: 0.03 to 20%

    Cardiac Output (CO)

    • Range: Cardiac Output: 0.2 - 15 liters per minute; Blood Temperature: 30 - 42°C; Injectate Temperature: 0 - 30°C

    Respiration

    • Range: Respiration rate: 0 - 200 breaths per minute; Base impedance: 100 - 1000 Ω at 52.6 kHz excitation frequency; Detection sensitivity: 0.4 to 10 Ω variation

    Temperature

    • Temperature Range: 0°C to 45°C (32°F to 113°F)
    • Display Resolution: ±0.1°C
    • ccuracy: ±0.1°C (25°C to 45°C) independent of sensor

    Carbon Dioxide (CO2)

    • Measurement Technique: Non-dispersive infrared absorption, dual wavelength ratiometric
    • Sensor Type: Novametrix Medical Systems’ Capnostat III
    • Measurement Ranges: Pi CO2/Fi CO2: 0 to 100 mmHg/0 to 13%; Pe CO2/Fe CO2: 0 to 100 mmHg/0 to 13%; RR: 0 to 120 breaths/min