top of page
DSC02125.jpg

Our Products

Mortara ELI 250c

Mortara ELI 250c

Call For PRICING

 

The GE Marquette Mac 1200 is a compact 12-lead ECG system. The MAC 1200 can be configurable for standard electrocardiography without analysis or to include a 12-lead analysis. The system offers a full-page printout and a display showing waveform ECG readings. The MAC 1200 is an easy-to-use system that offers a one-touch operation for acquisition, analysis, storage, and printing. The GE system includes EKG/ECG electrodes, chart paper, and lead wire.

      • Full-size keyboard is easy to use and clean
      • Large backlit, waveform LCD Display has contrasted adjustable
      • Integrated thermal printer for full-size paper reports
      • Display Options: Elected lead groups, operation mode, lead check, heart rate, AC filter, muscle her, ADS, gain speed, and patient information
      • Built-in rechargeable battery
      • Anti Drift System (ADS) automatically compensates for the baseline fluctuations that are caused by polarization voltage fluctuations at the electrodes
      • Baseline adjusts where the ECG presentation is shown with an averaged baseline
      • Electrode monitoring where there is an audible and visual indication on the LCD of disconnected electrodes or fine break
      • Automatic performance test upon power up, including verification of the signal path starting at the signal input
      • Width: 14.5 in. (370 mm)
      • Height: 3.7 in. (94 mm)
      • Depth: 12.6 in. (320 mm)
      • Weight: 12.4 lb (5.6 kg) with graphics display and battery

      Signal Processing

      • Acquisition: 12 leads - simultaneously
      • Signal input: Type CF according to IEC
      • Digital sampling rate: 1000 samples/second/channel
      • Dynamic range: Differential signals for AC voltage ±, 10mV Superimposed DC voltage (Polarization voltage) ±600mV
      • Resolution: 5 uV
      • Frequency response:0.04 - 150 Hz
      • Common mode rejection:> 140 dB
      • Input impedance: > 100 M ohms
      • Leakage current: < 10uA
      • Pacemaker detection sensitivity: All leads, duration 0.1 - 2.5 ms, amplitude > 5 mV

      Display

      • Type:LCD 320 x 240 pixel, backlit, Contrast adjustable
      • Displayed data: Selected lead group, operation mode, lead check, heart rate, AC filter, muscle her, ADS, gain, speed, name, ID, 3 ECG waveforms

      Writer

      • Type: Thermal-array print head
      • Resolution: Vertically 8 dots/mm horizontally 25um at 25 mm/s
      • Paper: 8.5 x 11 inch
      • Writer speed: 5, 25, 50 mm/s
      • Paper type: Z-fold

      Keyboard

      • Type: Membrane keypad with tactile feedback / 46 keys

      Special Functions

      • Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes
      • Baseline adjustment: ECG presentation on the averaged baseline
      • Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Every single electrode is monitored
      • Copy: In the automatic 12 lead modes, after ECG, recording, copies of the ECG can be printed
      • Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input

      Power Supply

      • Ratings: 10 - 120 V (0.32A) / 220 - 240 V (0.16A)
      • Frequency: 49 - 65 Hz
      • Battery type: NiCad, 18V, 1.4 Ah
      • Battery charge time: 4 hours
    Anchor 1